Chip Cooling Hits Record 1,570 W/cm² With Boiling Fluid

Peking University engineers built a chip-cooling system using boiling dielectric fluid that hit a record heat flux of 1,570 W/cm².

2 min read
Chip Cooling Hits Record 1,570 W/cm² With Boiling Fluid

Engineers at Peking University in Beijing have built a new chip-cooling system that uses a boiling, electrically non-conductive fluid to pull heat away from microchips, reaching a record heat flux of 1,570 watts per square centimeter, according to a study published in Nature Electronics.

The design, called HUMMC (horizontal-up manifold microchannel), feeds coolant horizontally through side inlets and vents the resulting vapor upward through separate vertical channels. The microchannels are etched directly into the silicon substrate beneath the chip's heated area, so the cooling fluid reaches as close as possible to the heat source.

Unlike traditional liquid-cooling systems that use water, the new design relies on a dielectric fluid called HFE-7100, which does not conduct electricity. That removes the risk of short circuits that comes with water-based cooling.

How the design works

The HFE-7100 fluid enters horizontally through side inlets, spreads through narrow microchannels where it heats up and boils, then the resulting mixture of liquid and vapor exits upward through vertical channels. Separating the incoming liquid path from the outgoing vapor path makes it easier to keep fresh coolant flowing in while clearing out bubbles faster, since built-up bubbles can disrupt heat exchange and destabilize cooling.

Record heat flux results

In testing, the system reached a critical heat flux of 1,570 W/cm² at a flow rate of 120 milliliters per minute. Critical heat flux is the maximum rate at which heat can be removed per unit of area before further increases in heat load start to degrade cooling performance.

By comparison, earlier dielectric-fluid cooling systems typically could not exceed 1,000 W/cm², even when the fluid was pre-cooled and pressure was increased. At a lower flow rate of 60 milliliters per minute, the new design still achieved about 1,200 W/cm², with hydraulic resistance 14% lower than conventional straight, parallel microchannel designs.

At peak heat load, the chip's temperature rose by almost 130°C above its starting point. In additional tests run for 10 minutes at heat fluxes between 1,000 and 1,400 W/cm², temperature fluctuations stayed within ±2°C and pressure swings within ±1.5 kilopascals.

What comes next

A key advantage of the design is that it can be built using standard microelectromechanical systems (MEMS) manufacturing techniques, the same processes used to make miniature silicon devices. That raises the possibility of integrating these cooling structures directly into existing semiconductor manufacturing lines. The researchers say the system's effectiveness on commercial processors has yet to be tested.

What happens next

The researchers say the design's effectiveness still needs to be tested on commercial processors.

Test yourself

  1. What critical heat flux did the new HUMMC cooling system achieve?

  2. Why does the new system use a dielectric fluid instead of water?

  3. What manufacturing technique could allow the cooling structures to be integrated into chip production?

Have your say

How important is solving chip-cooling challenges for the future of computing?

Where it happened

Beijing, China

Leave a comment

Your email address will not be published. Required fields are marked *